Air Conditioning Parts and Supplies
Removes debris and contaminants from AC Systems. Restores performance of AC System by removing carbon build up from heat transfer. Includes internal nitrogen regulator for use with European standard 1 liter nitrogen bottle. For Optional Block-Off and Flushing Fitting Kit See 530-69925
FEATURES: - Stainless steel ball valve controls - 1/4” SAE connection - Additional external container connection - External nitrogen bottle connection - Pump equipped with mechanical seal and PTFE gasket - Mechanical filter present at suction side SPECIFICATIONS: - Pump Flow Rate: 4 g/min (16 l/min) - Pump Motor: 300 watts - Pump Horsepower: 220-240V/50/60 Hz – 0.28 HP - Full Load Amperage 220-240V/50/60 Hz – 1.7 amps - Flush Container: 2.6 gal (10 l) - Hoses: 9 ft (3 m) flexible, clear coiled